Can a Tech Company Build a City? Ask Google

Sidewalk Toronto will become a 1,200-acre testing ground for new tech products

Posted on Feb 8 2018 by Anonymous

By SARAH BARNS

Sidewalk Labs, the urban innovation startup owned by Google’s parent company Alphabet, has announced a partnership with the City of Toronto to develop a new waterfront precinct. Time to ask Google: Can you build a city?

The Quayside precinct, dubbed “Sidewalk Toronto,” is to become a 500-hectare (1,236-acre) sandpit for testing a suite of new tech products. The aim is to radically reimagine the way a city is made. (Further reading: Creative City, Smart City … Whose City Is It?.)


Tags: , , , , , ,

Image Credits:

  1. Blair Stirrett via Flickr

guest-blogsheader image

Toronto Passive: High-Efficiency Lighting

Sorting through the specs for commercially available LEDs takes some patience

Posted on May 4 2017 by Lyndon Than

Editor's Note: Lyndon Than is a professional engineer and Certified Passive HouseA residential building construction standard requiring very low levels of air leakage, very high levels of insulation, and windows with a very low U-factor. Developed in the early 1990s by Bo Adamson and Wolfgang Feist, the standard is now promoted by the Passivhaus Institut in Darmstadt, Germany. To meet the standard, a home must have an infiltration rate no greater than 0.60 AC/H @ 50 pascals, a maximum annual heating energy use of 15 kWh per square meter (4,755 Btu per square foot), a maximum annual cooling energy use of 15 kWh per square meter (1.39 kWh per square foot), and maximum source energy use for all purposes of 120 kWh per square meter (11.1 kWh per square foot). The standard recommends, but does not require, a maximum design heating load of 10 W per square meter and windows with a maximum U-factor of 0.14. The Passivhaus standard was developed for buildings in central and northern Europe; efforts are underway to clarify the best techniques to achieve the standard for buildings in hot climates. Consultant who took a year off from work to design and build a home with his wife Phi in North York, a district of Toronto, Ontario. A list of Lyndon's previous blogs at GBAGreenBuildingAdvisor.com appears in the sidebar below. For more, you can follow his blog, Passive House Toronto. This post originally appeared in November 2014.


Tags: , , ,

Image Credits:

  1. Lyndon Than

guest-blogsheader image

Toronto Passive: Removable Basement Floors

All the insulation in the house is inside the structural building envelope — and that includes the mineral wool insulation in the basement

Posted on Mar 6 2017 by Lyndon Than

Editor's Note: Lyndon Than is a professional engineer and Certified Passive HouseA residential building construction standard requiring very low levels of air leakage, very high levels of insulation, and windows with a very low U-factor. Developed in the early 1990s by Bo Adamson and Wolfgang Feist, the standard is now promoted by the Passivhaus Institut in Darmstadt, Germany. To meet the standard, a home must have an infiltration rate no greater than 0.60 AC/H @ 50 pascals, a maximum annual heating energy use of 15 kWh per square meter (4,755 Btu per square foot), a maximum annual cooling energy use of 15 kWh per square meter (1.39 kWh per square foot), and maximum source energy use for all purposes of 120 kWh per square meter (11.1 kWh per square foot). The standard recommends, but does not require, a maximum design heating load of 10 W per square meter and windows with a maximum U-factor of 0.14. The Passivhaus standard was developed for buildings in central and northern Europe; efforts are underway to clarify the best techniques to achieve the standard for buildings in hot climates. Consultant who took a year off from work to design and build a home with his wife Phi in North York, a district of Toronto, Ontario. A list of Lyndon's previous blogs at GBAGreenBuildingAdvisor.com appears below. For more, you can follow his blog, Passive House Toronto.


Tags: , , , ,

Image Credits:

  1. Lyndon Than

guest-blogsheader image

Toronto Passive: Walls, Roof, and an Elevator

The house begins to take shape with double-stud exterior walls, solid plank sheathing, and the roof

Posted on Feb 6 2017 by Lyndon Than

Editor's Note: Lyndon Than is a professional engineer and Certified Passive HouseA residential building construction standard requiring very low levels of air leakage, very high levels of insulation, and windows with a very low U-factor. Developed in the early 1990s by Bo Adamson and Wolfgang Feist, the standard is now promoted by the Passivhaus Institut in Darmstadt, Germany. To meet the standard, a home must have an infiltration rate no greater than 0.60 AC/H @ 50 pascals, a maximum annual heating energy use of 15 kWh per square meter (4,755 Btu per square foot), a maximum annual cooling energy use of 15 kWh per square meter (1.39 kWh per square foot), and maximum source energy use for all purposes of 120 kWh per square meter (11.1 kWh per square foot). The standard recommends, but does not require, a maximum design heating load of 10 W per square meter and windows with a maximum U-factor of 0.14. The Passivhaus standard was developed for buildings in central and northern Europe; efforts are underway to clarify the best techniques to achieve the standard for buildings in hot climates. Consultant who took a year off from work to design and build a home with his wife Phi in North York, a district of Toronto, Ontario. A list of Lyndon's previous blogs at GBAGreenBuildingAdvisor.com appears below. For more, you can follow his blog, Passive House Toronto.


Tags: , , ,

Image Credits:

  1. All photos and illustrations: Lyndon Than